Specifications
Approvals and Certifications
  SPECIFICATIONS

Scanning Chamber
  • Tunnel opening: 100 cm (w) x 60 cm (h) (3.2 ft x 2 ft)
  • Weight (uncrated): 6,078 kg (13,400 lbs)
  • Length (with conveyer): 4.84 meters (190.6 inches)
  • Width: 2.21 meters (87 inches)
  • Height: 229 cm (90 inches)
  • Conveyer speed: up to 45 feet per minute (.22 m/s)
Power Specification, Scanning Enclosure
  • 400/460/575 +/- 5% 50/60 Hz 7.5kVA 3 phase 3 wire
  • Optional accessories can increase power requirements
Power (X-ray)
  • Single-level, stable high-voltage supply--stationary high-voltage distribution system insures reliability
  • Operates at 160 kV
Detector Data
  • Photon counting, multi-spectral detector imaging system using a monolithic chip.
Environmental
  • Operating temperature: 0 C to 40 C
  • Storage temperature: -20 C to 60 C
  • Humidity: 85% non-condensing
System Operational Options
  • Fully integrated
  • Partially integrated or stand alone
  • Multiplexed
  • Extended service package
Technology
  • Advanced technology effective atomic number analysis combined with computed tomography density and image generation
Data Processing Rack
  • CT Rack Dimensions (L x W x H) (2 racks together): 1.52 m x 107 m x 2.08 m; 60 in. x 42.1 in. x 82 in.
  • Shipping Dimensions (L x W x H): 091 m x 1.22 m 2.21 m; 36 in x 48 in x 87 in
    NOTE Dimensions are for each of 2 racks shipping on separate skids
  • Weight: 1028 kg; 2267 lbs (total, both racks and contents)
  • Shipping Weight: CT Rack weight plus 45 kg; 100 lbs for both racks
  • Operating Temperature Range: 10 - 35 °C; 50 – 95 °F
  • Shipping and Storage Temperature Range: -20 to 60 °C; -4 to 140 °F
  • CT Rack Power Requirements: 208/240 Volt, Three-Phase, 50 / 60 Hz, 10 kVA 3 wire. (In Europe, Asia, etc., the 220 Volts is derived from a WYE system by connecting from the Line to the Neutral on a 380, 400, or 415 Volt WYE system.)
  • Operating Ambient Humidity Requirements: 5% to 85% RH non-condensing
  • Heat Output: 5600 W; 19100 Btu/hr
    NOTE: Heat output is total for two racks
Operator Workstations
  • Manipulatable color 3-D volumetric image
  • Individual color slice images
  • 2-D Radiograph
  • Dimensions (L x W x H):
    • Processor: 406 mm x 191 mm x 16.25 mm; 16 in. x 7.5 in. x 0.64 in.
    • Monitor: 458 mm x 456 mm x 468 mm; 18.03 in. x 17.95 in. x 18.42 in.
  • Shipping Dimensions (L x W x H):
    • Processor: 500 mm x 220 mm x 20 mm; 19.7 in. x 8.7 in. x 0.79 in.
    • Monitor: 500 mm x 500 mm x 500 mm; 19.7 in. x 19.7 in. x 19.7 in.
  • Weight:
    • Processor: 11.4 kg; 25.0 lb
    • Monitor: 21.25 kg; 46.85 lb
  • Shipping Weight:
    • Processor: 11.4 kg; 25.0 lb
    • Monitor: 24.6 kg; 54.23 lb
  • Operating Temperature Range:
    • Processor: 10 to 35 °C; 50 to 95 °F
    • Monitor: 5 to 40 °C; 41 to 104 °F
  • Shipping and Storage Temperature Range: -20 to 65 °C; -4 to 149 °F
  • Operating Workstation Power Requirements: 120/230 Volt, 50 / 60 Hz, two outlets
  • Operating Ambient Humidity Requirements:
    • Processor: 8% to 80%
    • Monitor: 10% to 90%
  • Shipping Ambient Humidity Requirements:
    • Processor: 8% to 80%
    • Monitor: 10% to 95%
  • Heat Output: 257 Btu/hr (75 watts)
Next-generation technology that rapidly detects and identifies all bulk and thin sheet explosive materials in checked airport baggage.